Hindrance of semiconductor process — static — solved with the sole of a shoe

The research team led by Professor Ju-Hyuck Lee of the Department of Energy Science and Engineering at DGIST (President Yang Kuk) developed a static prevention technology using a triboelectric nanogenerator through collaborative research with Dr. Wanchul Seung of Global Technology Research at Samsung Electronics. The findings of this study facilitate improved and more efficient static prevention with commercialization potential by expanding the application range of triboelectric nanogenerators.

Recent developments in semiconductors and small electronic components have increased the interest in static prevention, as static damage to small components leads to an increased defect rate. Currently, companies use a combination of various anti-static products such as wired grounding wristbands, antistatic mats, shoes, and ionizers. However, these methods result in increased equipment costs and operational inconveniences. Therefore, an efficient and simple static-prevention method is required.

The research team focused on the cause of static conditions. The human body is generally static owing to the electric potential difference between the body and an object when both come in contact. The cause of this electric potential difference has been found in recent studies on triboelectric series between materials. Because the human skin is on the positive (+) side of the triboelectric series, it becomes positively charged (anode) when it contacts typically used objects such as shoes and clothes, sharply increasing the body electric potential to positive (+), causing static. The measurement results of the research team showed that the electric potential of the body increased by more than 100 V after walking for approximately 10 s.

As a solution, a method for transmitting negative charges to the body was developed. Using a triboelectric nanogenerator, the physical energy generated through body movements, such as walking, can be converted into electrical energy. A rectifier provides a negative charge to the body. The team observed that the electric potential of the body decreased to a negative value. The team also confirmed that the rate of decrease in the body electric potential varies based on the output (voltage, current, and charge) of the triboelectric nanogenerator, and the type and surface area of the discharger. A static prevention system with an appropriate triboelectric nanogenerator was applied to the sole of the shoe using the aforementioned variables. Consequently, an increase in the electric potential of the body was prevented. This is significantly more efficient than existing wireless antistatic wristbands in the market.

Professor Ju-Hyuck Lee of the Department of Energy Science and Engineering at DGIST stated, “This study provides a highly cost-efficient method with high-commercialization potential and is expected to effectively prevent static without causing inconvenience to work compared to the existing static prevention equipment.”

This study was conducted with support from the Ministry of Science and ICT National Research Foundation of Korea (NRF). The findings of this study were published in “Nano Energy,” one of the top-ranked international academic journals in energy engineering (first author: Cheoljae Lee, combined master’s and doctoral program students of the Department of Energy Science and Engineering).

Story Source:

Materials provided by DGIST (Daegu Gyeongbuk Institute of Science and Technology). Note: Content may be edited for style and length.

For all the latest Technology News Click Here 

Read original article here

Denial of responsibility! TechAI is an automatic aggregator around the global media. All the content are available free on Internet. We have just arranged it in one platform for educational purpose only. In each content, the hyperlink to the primary source is specified. All trademarks belong to their rightful owners, all materials to their authors. If you are the owner of the content and do not want us to publish your materials on our website, please contact us by email – [email protected]. The content will be deleted within 24 hours.